This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
This Website Uses Cookies
By closing this message or continuing to use our site, you agree to our cookie policy. Learn More
This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
PM Engineer logo
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
PM Engineer logo
  • Home
  • Magazine
    • Current Issue
    • Digital Edition
    • Archives
    • Radiant & Hydronics Report
    • Green Plumbing & Heating
    • Fire Protection & Design Special Section
    • NSF Design Special Section
    • Radiant Comfort Guide
    • PVF Outlook
    • Ad Index
  • Market Sectors
    • Green Plumbing
    • Green Mechanical Systems
    • Codes
    • Fire Protection
    • Radiant/Hydronics
    • Solar Thermal/Geothermal
    • Bath & Kitchen
    • Water Treatment
    • Technology
  • eNewsletter
    • Supply House Times e-news
    • pme eNewsletter Archives
    • Radiant & Hydronics eNews Archives
    • Bath & Kitchen Pro eNews Archives
    • Western Plumbing News Archives
    • Subscribe to Plumbing Group eNewsletters
  • Columnists
    • Julius Ballanco on Codes
    • Editor's Note
    • John Siegenthaler: Renewable Heating Design
    • Dan Holohan: Heating Help
    • Ray Wohlfarth: The Boiler Room
    • Jacqueline Wilmot: Fire Protection
    • Christoph Lohr: Professional Development Pipeline
    • Ethan Grossman: Water Cooler Conversations
    • Blog
  • Multimedia
    • PME AHR Expo 2019 Videos
    • pme Network Videos
    • eBook
    • Interactive Spotlights
    • Photo Gallery
    • Podcasts
    • Webinars
  • Products
  • More
    • History of Plumbing
    • Industry Calendar
    • Custom Content & Marketing Services
    • Classified Ads
    • Market Research
    • Bookstore
    • Continuing Education
  • Directories
    • B.I.G. Book
    • Rep Locator
  • Contact
    • Contact Us
    • Advertise
    • Editorial Submission Guidelines
Home » That's a wrap
Julius Ballanco on CodesPlumbing & Mechanical & Fire CodesColumnists

That's a wrap

December 1, 2012
Julius Ballanco P.E., CPD
KEYWORDS ICC / international plumbing code
Reprints
No Comments

2015 International Plumbing Code features several surprise changes.



A new requirement in the 2015 IPC states a quick transaction facility with a customer area less than 300 sq. ft. (such as an ATM in a small area of a building) does not require public toilet facilities. Photo credit: istockphoto.com/Dombili


 

Here we are in the holiday season and the International Code Council delivered a present - the 2015 International Plumbing Code.

That’s right, ICC just completed the 2015 Plumbing Code - emphasis on the year 2015. Yes it appears to be a little early for completing the 2015 Code, but that is how the new three-year cycle works with ICC. The only changes that can be made to the 2015 Plumbing Code are to the administrative section of the code located in Chapter 1.

The final voting occurred at ICC’s recent annual meeting in Portland, Ore., and presented some interesting results. The hearing drew a crowd of about 1,000 people onsite and many more watching online. When electronic voting took place there was constantly more than 200 votes cast by jurisdictional members.



Water shockers

One of the biggest surprises is the approval of the new rainwater sizing requirements resulting from the ASPE Research Foundation’s study. The new sizing method will require manufacturers to provide flow data to plumbing engineers for sizing storm drainage piping. A plumbing engineer will be required to calculate the ponding level at the roof drain during a 100-year storm of 60 minutes in duration. As one colleague commented after reading the report, the results will either be smaller or same-size drains and larger pipe. That’s an accurate overview of that change.

Another major change is the rewrite of the graywater and rainwater collection chapters. Currently, there is only Chapter 13 entitled “Gray Water Recycling Systems.” That chapter has been renamed “Non-Potable Water Systems.” A new Chapter 14 is entitled “Subsurface Landscape Irrigation Systems.” In effect, the old Chapter 13 is divided into two chapters with greatly expanded requirements. Nonpotable water can now be provided from any source other than wastewater containing urine or fecal matter. The chapter contains requirements for storage, filtering, disinfection and materials.

One area always subject to a lot of discussion is fixture requirements - how many, where they are located and what type. Many of the changes that received public comments were denied by the membership. The approved changes include a new exception for public fixtures in quick transaction buildings. As the code currently reads, if you have an ATM available to the public inside a small area of a building, toilet facilities must be provided. The new requirement states that a quick transaction facility with a customer area less than 300 sq. ft. does not require public toilet facilities. This would also include dry cleaners, pizza takeout, newspaper stands and similar facilities.

Bottled water dispensers were added as equivalent to a drinking fountain. However, a minimum of 50% of the fixtures must be drinking fountains. With the added definition of “water dispenser,” even a dispenser on a refrigerator would count toward the requirement for drinking fountains.

A new standard has been added for accessible fixture coverings. Most of the major manufacturers of trap and riser protective covers already are listed to ASME A112.18.9.



Green thumbs down

A number of green issues were denied by the ICC membership. The concern was to not put too much green in the plumbing code when it cannot be justified as protecting public health, safety or welfare. One change that was defeated is a proposal to require a water-supplied fixture to be located upstream of non-water urinals. This was placed in the Green Code, but not the Plumbing Code. A follow-up code change will now be submitted to the Green Code to remove the requirement.

All changes to the hot water recirculation requirements also were defeated. One change would have restricted the pump on recirculating systems to be operated by the user of the fixture, a flow switch or similar activation. The concern is the requirement would not permit the continuous operation of a pump.

Also denied was the lowering of plumbing fixture flow rates. With the removal of the federal pre-emption, this was the first attempt to add more water conserving requirements to the Plumbing Code since the early 1990s. While the flow rates were not lowered, the sizing requirements were changed to reflect lower water uses. The design of the water distribution system can now take into account lower water supply rates. This will allow plumbing engineers to use more realistic values for sizing the distribution system.



Pipe comings and goings

There were some shocking results for drain-waste-vent requirements. The temperature limitation of 140° F was removed from the code. Any temperature of waste can discharge to the drainage system. However, when the waste temperature is greater than 140°, the piping material must be rated for the higher temperature. Many thought the limitation of 140° was based on the use of plastic pipe. The requirement predates plastic pipe and was originally added to the code based on the temperature in which the galvanizing is removed from steel pipe. Both PVC and ABS can handle temperatures higher than 140°.

A new code section was added for replacement of underground sewers by pipe-bursting methods. The material required for the replacement is high molecular weight polyethylene.

Another plastic pipe change removes the requirement to prime PVC joints for non-pressure DWV installations. For many old-timers in the audience, the use of primer always elicited hours of testimony in past years. Many thought primer would never be removed for PVC joints. However, testimony was overwhelmingly in support of this change with no real opposition.

A new requirement for food-handling sinks requires each sink drain to discharge independently to a waste receptor (indirect waste). This has been standard practice in plumbing engineering for many years, but it was never a code requirement.

Trap seal protection was revised and allows one of four methods of protecting the trap seal. The methods previously allowed were the water-supplied trap seal primer and the waste-supplied trap seal primer. Added to the allowable methods are a reclaimed water trap seal primer and a barrier-type trap seal protection device. The latter must conform to ASSE 1072.

The new code will not be published for another year-and-a-half. As previously mentioned, the administrative section will be up for review in the 2013 code change cycle.

I would like to wish all of you a very Merry Christmas, Happy Hanukkah, Happy Holidays and a Happy New Year.

Enjoy your family and forget about codes and standards for a few days.



Links

  • Like PM Engineer on Facebook!
  • Follow pme on Twitter!
  • Contact PM Engineer

Subscribe to PM Engineer

Recent Articles by Julius Ballanco

Julius Ballanco: Not much changed at IAPMO

Julius Ballanco: The ins and outs of water pathogens, including Legionella

Julius Ballanco: The move to lower global-warming refrigerants

Julius Ballanco: Are composting toilets plumbing?

Julius Ballanco: The cured-in-place debate

Ballancojuliusvwhite_200

Julius Ballanco, P.E., CPD, F-ASPE, is president of J.B. Engineering and Code Consulting, P.C. in Munster, Ind. He can be reached at by email at jbengineer@aol.com.

Related Articles

International Plumbing Code change will require a shutoff valve to isolate a tenant’s water supply

Julius Ballanco: Lead in drinking water continues to be a hot topic for NSF

A lesson in steam heating that will save you a headache

A Plumbing Code Design Manual You Need

Related Events

ICC, PMI Webinar: Changes to the 2015 IPC

You must login or register in order to post a comment.

Report Abusive Comment

Subscribe For Free!
  • Print & Digital Edition Subscriptions
  • eNewsletters
  • Online Registration
  • Subscription Customer Service

More Videos

Popular Stories

John Siegenthaler: Renewable Heating Design

John Siegenthaler: Pellet-fired boilers need thermal storage

Chis Wysoczanski, P.E.

2019 pme Mechanical Engineer of the Year: Fitzemeyer & Tocci's Chris Wysoczanski, P.E.

Julius Ballanco

Julius Ballanco: Not much changed at IAPMO

Ethan Grossman

Ethan Grossman: Getting dirty in engineering

Christoph Lohr

Christoph Lohr: Looking at the importance of personality metrics

Mechanical Engineer of the Year 2017 360

Events

December 30, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

View All Submit An Event

Products

2020 National Plumbing & HVAC Estimator

2020 National Plumbing & HVAC Estimator

See More Products

PME-PlumberEngineer2017_360.png


PME Rep Locator

PM Engineer Magazine

PME November 2019

2019 November

Check out the November 2019 edition of PME: PME's Mechanical Contractor of the Year, drainage trends, pellet-fired boilers, flue gas venting, and much more!
View More Create Account
  • Resources
    • List Rental
    • Reprints
    • eNewsletters
    • Contact Us
    • Privacy Policy
    • Editorial Submissions
  • Want More?
    • Subscribe
    • Industry Links
    • Connect
    • Survey And Sample
  • Plumbing Group
    • Plumbing & Mechanical
    • Supply House Times
  • Advertise
    • Advertise
    • Plan For 2020!

Copyright ©2019. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing