This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
This Website Uses Cookies
By closing this message or continuing to use our site, you agree to our cookie policy. Learn More
This website requires certain cookies to work and uses other cookies to help you have the best experience. By visiting this website, certain cookies have already been set, which you may delete and block. By closing this message or continuing to use our site, you agree to the use of cookies. Visit our updated privacy and cookie policy to learn more.
PM Engineer logo
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
PM Engineer logo
  • Home
  • Magazine
    • Current Issue
    • Digital Edition
    • Archives
    • Radiant & Hydronics Report
    • Green Plumbing & Heating
    • Fire Protection & Design Special Section
    • NSF Design Special Section
    • Radiant Comfort Guide
    • PVF Outlook
    • Ad Index
  • Market Sectors
    • Green Plumbing
    • Green Mechanical Systems
    • Codes
    • Fire Protection
    • Radiant/Hydronics
    • Solar Thermal/Geothermal
    • Bath & Kitchen
    • Water Treatment
    • Technology
  • eNewsletter
    • Supply House Times e-news
    • pme eNewsletter Archives
    • Radiant & Hydronics eNews Archives
    • Bath & Kitchen Pro eNews Archives
    • Western Plumbing News Archives
    • Subscribe to Plumbing Group eNewsletters
  • Columnists
    • Julius Ballanco on Codes
    • Editor's Note
    • John Siegenthaler: Renewable Heating Design
    • Dan Holohan: Heating Help
    • Ray Wohlfarth: The Boiler Room
    • Jacqueline Wilmot: Fire Protection
    • Christoph Lohr: Professional Development Pipeline
    • Ethan Grossman: Water Cooler Conversations
    • Blog
  • Multimedia
    • PME AHR Expo 2019 Videos
    • pme Network Videos
    • eBook
    • Interactive Spotlights
    • Photo Gallery
    • Podcasts
    • Webinars
  • Products
  • More
    • History of Plumbing
    • Industry Calendar
    • Custom Content & Marketing Services
    • Classified Ads
    • Market Research
    • Bookstore
    • Continuing Education
  • Directories
    • B.I.G. Book
    • Rep Locator
  • Contact
    • Contact Us
    • Advertise
    • Editorial Submission Guidelines
Home » Protection for Post- Mix Carbonators

Protection for Post- Mix Carbonators

July 28, 2000
Reprints
No Comments
One of the common questions received in the Foundation for Cross-Connection Control and Hydronic Research office has to do with the level of backflow protection needed on post-mix soft drink carbonators. The post-mix soft drink carbonator takes water and carbonates it using carbon dioxide (CO2) from a refillable tank.This carbonated water is then mixed with syrup to produce the soft drinks served at restaurants, movie theaters and other establishments.

Initially, one wonders whether any backflow protection is needed. After all, we drink the sodas, don't we? What would be the problem if some soda got into the drinking water? Further investigation shows that the CO2 is under pressure and could, thus, create backpressure into the drinking water system. In such a case, when backpressure is present, a minimum of a double check valve assembly is typically required. There would, however, seem to be no contaminants (i.e., health hazards) which would warrant a reduced pressure principle assembly.

Yet, further investigation demonstrates that there is a potential for the CO2 or carbonated water to backflow into the water supply copper piping. This is where the problem occurs. The acidic carbonated water or carbon dioxide may leach the copper out of the copper piping. This may be detected by the discoloration of the water (i.e., blue water), or air (i.e., carbon dioxide) coming out of nearby faucets, or an "off-taste" in the soft drink being served. Ingesting large amounts of copper can cause acute gastrointestinal distress, vomiting and diarrhea. Should a person have food in his/her stomach, the proteins in the food may minimize the irritating effects of the copper. Because of this possibility of the leaching of the copper piping, there has been concern with any copper alloy being exposed to the carbonated water or CO2 . Therefore, we now have reason to need a reduced pressure principle assembly. However, to complicate matters, the bronze materials from which most RPs (i.e., 2" and smaller) are constructed fall into the "copper alloy" category. This raises another issue of concern. To eliminate copper alloy in the water line to the carbonator, some jurisdictions have been requiring a stainless steel bodied RP as the backflow protection. However, it is the Foundation's position that an RP, bronze, plastic or stainless steel bodied, is acceptable with the following guidelines:

    1. The carbonator pump does not exceed 175 psi, so that the RP is capable of handling the potential backpressure. (Of course, the backpressure would only occur if the non-vented double ball checks at the carbonator pump fail. For the RP to be contacted by the carbonated water or CO2 , the second check of the RP would also have to fail so that the CO2 could travel back towards the RP.)

    2. Piping from the RP to the carbonator is not made of a copper alloy (i.e., copper tubing). Reinforced plastic, rubber, or stainless steel tubing is to be used.

    3. The RP is field-tested in-situ at least annually.

    4. The RP is installed in compliance with local administrative authority requirements.

If these criteria are met, there is no reason to require a stainless steel assembly. A bronze reduced pressure principle assembly should provide adequate backflow protection, and the potential of carbonated water coming in contact with the assembly is minimal.

Subscribe to PM Engineer

Related Articles

Backflow For Post-Mix Dispensing Systems

Southland Industries deals with difficult codes for new mixed-use Vegas facility

New Scald Prevention Requirements for Thermostatic Mixing Valves

Comprehensive BIM modeling sets the path for mixed-use complex in Miami

You must login or register in order to post a comment.

Report Abusive Comment

Subscribe For Free!
  • Print & Digital Edition Subscriptions
  • eNewsletters
  • Online Registration
  • Subscription Customer Service

More Videos

Popular Stories

John Siegenthaler: Renewable Heating Design

John Siegenthaler: Pellet-fired boilers need thermal storage

Chis Wysoczanski, P.E.

2019 pme Mechanical Engineer of the Year: Fitzemeyer & Tocci's Chris Wysoczanski, P.E.

Julius Ballanco

Julius Ballanco: Not much changed at IAPMO

Ethan Grossman

Ethan Grossman: Getting dirty in engineering

Christoph Lohr

Christoph Lohr: Looking at the importance of personality metrics

Mechanical Engineer of the Year 2017 360

Events

December 30, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

View All Submit An Event

Products

2020 National Plumbing & HVAC Estimator

2020 National Plumbing & HVAC Estimator

See More Products

PME-PlumberEngineer2017_360.png


PME Rep Locator

PM Engineer Magazine

PME November 2019

2019 November

Check out the November 2019 edition of PME: PME's Mechanical Contractor of the Year, drainage trends, pellet-fired boilers, flue gas venting, and much more!
View More Create Account
  • Resources
    • List Rental
    • Reprints
    • eNewsletters
    • Contact Us
    • Privacy Policy